·þÎñÈÈÏß
135-0983-1315
°²×°ÒªÇó¼°¼ì²éµ÷Õû
Check Before Operation
1.¿¾ÏäµÄ°²ÖÃËùÔÚÒªÇó:
Fixing Requirement
1.1 µØÃæÐëˮƽ¡£
Keep horizontal.
1.2 ͨ·çÐëÁ¼ºÃ£¬Âä³¾Á¿½ÏÉÙ¡£
Well ventilation and dustless environment.
1.3 ²»Òª°²ÖÃÔÚʪÈóµØ·½¡£
Do not place the oven in humid space.
1.4 ²»ÒªÆضÔÚÒ×ȼ»ò¸¯Ê´ÐÔÆøÌåÏÂ(ÌØÊ⿾Ïä³ýÍâ)¡£
Do not expose under flammable or corrosive atmosphere(except specific oven).
1.5 ¾¡¿ÉÄÜʹ¿ÉȼÎïÔ¶Àë¡£
Keep away from flammable material as possible.
1.6 »·¾³Î¶ÈÎð¹ý¸ß£¬×îºÃÔÚÊÒΡ«40¡æ·¶Î§ÄÚ¡£
Keep the Temp. between room Temp.¡«40¡æ.
2.¿¾ÏäµÄ°²Öüä¸ôÒªÇó:
Placing Interval
2.1 ÀíÏë²Ù×÷»·¾³»úÉí¸÷·½¾àǽÖÁÉÙ60¹«·ÖÒÔÉÏ¡£
Ideal operating environment is up than 60cm away from the wall
2.2 ÀíÏë²Ù×÷»·¾³»úÉíÓë»úÉí¼ä¸ôÖÁÉÙ60¹«·ÖÒÔÉÏ¡£
Up than 60cm apart from machine to machine.
3.¿¾ÏäµÄµçÔ´°²×°ÒªÇó:
Electronic Installation Requirement
3.1 ÇëÒÀµçÆ÷Ãú°åÉÏËù¶©Ö®µçÔ´¹æ¸ñ½Óµç¡£
Please follow the mains which indicate on the electrical plate
3.2 µçѹ±ä»»ÂʱØÐëÔڶֵ¡À5£¥ÄÚ¡£
Voltage fluctuation must be within rated ¡À5£¥
3.3 ΪÖÆÖ¹µç»÷ÒâÍâ·¢Éú£¬»ų́×Ô¼º±ØÐë½ÓµØ¡£(ÒÀµç¹¤¹æÔòµÚÈýÖÖ
½ÓµØ·¨ÊµÊ©¶ÔµØµç×è(100¦¸ÒÔÏÂ)¡£
The oven must be grounded to avoid the electric shock. (Please
observe the Electronic Regulation to use the third grounding manner(Under 100¦¸)¡£
3.4 ²»Ðн«ÂÌÉ«½ÓµØÏß½ÓÖÁÍß˹»òË®¹ÜÉÏ¡£
Never connect the ground cable in green with gas or liquid pipe
3.5 ²»Ðн«ÓЩµç¶Ï·Æ÷¿¾ÏäÓëÎÞ´Ë×°Öÿ¾Ïä¹²Ïí½ÓµØÏß·¡£
Please do not share the ground cable with any other machine
4.¿¾ÏäµÄˮƽµ÷Õû:
Horizontal Adjustment
»ų́¶¨Î»ºó£¬ÐëÏȵ÷Õûˮƽ£¬»ų́ÉÏÓÐ4֧ˮƽµ÷ÕûÂÝË¿½Å£¬ÓÃÓÚ¶¨Î»¼°Ë®Æ½µ÷Õû¡£
Adjust the horizontal of oven after mounting. There are four adjustable leveling screws below the oven, twist them to adjust the horizontal
5.¿¾ÏäµçÔ´½ÓÏß:
Connect In Electric
»ų́¶¨Î»Íê³Éºó£¬¿ÉÓÉ»ų́ºó·½Ö®µçÔ´µçÀÂÏߣ¬²¢ÒÀ½ÓÏ߶Ë×Ó°åÉÏÖ®±êʾ¹æ¸ñÍê³ÉµçÔ´½ÓÏßÖ®ÊÂÇ飨´ËÏîÊô³ýÍ⹤³Ì£©¡£
Afterward mounted the oven, connect the cable into power supply by mark and electric specification
6.¿¾ÏäµÄÅÅ·ç¹Ü½ÓÐø:
Exhaust Supple Pipe
»ų́¶¨Î»ºó£¬Ð뽫ÅÅ·ç¹Ü½ÓÉÏ?4¡±Ö®ÅÅ·ç¹Ü¡£
*µ±¿¾ÏäÄں濾Îï»á·¢ÉúÓÍÑÌʱ£¬¿ÉÒÔÊʵ±¼Ó´óÅÅÆøÁ¿¡£
Connect the exhaust supple pipe(?4) into exhaust.
when there is too much exhaust fume gas, could increase the flow
Capacity.
7.¿¾ÏäµÄËÍ·çÂí´ïµ÷Õû:
Adjust the exhaust motor
Çë¼ì²éËÍ·çÂí´ïתÏò£¬Ó¦ÓëÂí´ïÉÏÌùʾµÄתÏò±êÇ©Ò»Ö¡£ÈçתÏò´íÎó£¬Çë´ò¿ªÉϸÇÒÀÂí´ï½ÓÏ߸ü»»×ªÏò¡££¨Ò»°ã³ö³§Ç°¶¼Óе÷Õû£¬ÎÞÐè±ä»»£©
Please check the rotating direction of the motor£¬It should be in accordance with the label. If the direction is reverse, please open the lid of the motor then change the wiring.£¨Normally, we¡¯ve set it before ex-work.£©
1.Íê³É±¨¾¯:ºæ¿¾Íê³Éʱ´Ë·äÃùÆ÷Ãù½Ð;
COMPLETE ALARM :when bake finish the alarm sound will loud;
2.µçԴָʾ:ÈôµçÔ´¿ª¹Ø¡°ON¡±ºó£¬´ËָʾµÆÁÁÆð;
POWER INDICATOR : The light on when power supply switch ¡°on¡±;
3.¹ÊÕϱ¨¾¯:³¬ÎÂʱ´Ë·äÃùÆ÷Ãù½Ð;
FAULT ALARM:when temperature over setting value, the alarm sound will
Loud;
4.µçÁ÷±í:ÏÔʾ¼ÓÈÈÆ÷Ö®µçÁ÷;
AMMETER: To display the current of the heater;
5.ζȿØÖÆÆ÷:É趨Óë¿ØÖƸ÷¶Î¼ÓÈÈÆ÷֮ζÈ;
TEMPERATURE CONTROLLER: To set and control the temperature in
each unit;
6.³¬Î±£»¤Æ÷:É趨³¬ÎÂζȣ¬Æð±£»¤×÷ÓÃ;
OVER TEMPERATURE PROTECTOR:Set the Temp. of over value£¬to
prevent over Temp;
7.Æô/Í£¿ª¹Ø:°´´Ë¿ª¹Ø±ÕºÏºó£¬¿ØÖÆÏß·¿ªÊ¼Í¨µç;
START/STOP SWITCH:Press this button to start the control system;
8.¼ÆʱÆ÷:»ų́ºãμÆʱÓÃ;
TIMER:When bake temperature arrive at, timer start counting bake timing;
9.ζȼǼÆ÷:¼Ç¼¯ÄÚÁùµãζÈ;
TEMP RECORDER:Recording the chamber temperature;
10.¼ÓÈÈ¿ª¹Ø:°´´Ë¿ª¹Ø±ÕºÏºó£¬µçÈȹÜͨµç¼ÓÈÈ.
HEATING SWITCH:Press this button to start the heater.